Page 1 - Pulse-Jet

Installation, Operation,& Maintenance ManualUnique Design & Engineering Approaches for Industrial ApplicationsCAMCORPPulse-JetFilter Cartridge

Page 2 - TABLE OF CONTENTS

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 3 - Installation Setting Up Your Unit CAMCORP dust collectors are shi

Page 3

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Setting Up Your Unit (continued) Step 4: Check the top of the dirty air plenum

Page 4

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Setting Up Your Unit (continued) Attach tag lines at several locations to help

Page 5 - Examples of Safety Stickers

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Setting Up Your Unit (continued) The firing sequence of the diaphragm valves o

Page 6 - Section 2 - Receiving

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Auxiliary Equipment: All auxiliary equipment must be installed according to i

Page 7 - Storage Recommendations

INSTALLATION INSTRUCTIONSBottom LoadCartridge FilterElements-continued-1. Before entering the dust collector and beginning the installation procedure,

Page 8

Operation Procedures for Bottom Load Collectors • Leave the timer adjustments set as specified by the baghouse manufacturer until operation stabilize

Page 9

INSTALLATION INSTRUCTIONSTop Load Filter Elements-continued-1. Remove old bags and cages from the collector. The clean air plenum should be thoroughl

Page 10 - Section 3 - Installation

Installation of Snapband Retainers for Top Load Filter ElementsNOTE: Asnapband retainer has been shipped with every top load Filter Element. If you do

Page 12

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com TABLE OF CONTENTS Section 1 - SAFETY Safety Recommendations ...

Page 15 - INSTALLATION INSTRUCTIONS

Section 4 - Operation Operating Principle A. Solids laden air or gases enter the unit at the hopper or housing inlet. B. Air passes through the f

Page 16

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Start-Up Checklist Installation Make sure the unit is secured to the floor or

Page 17

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Start-Up Checklist (continued) Explosion Relief Panels – Shear Bolt Style (whe

Page 18

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Start-Up Checklist (continued) With the compressed air system operating, energ

Page 19

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Start-Up Dust Control Systems Fan or Blower System Start the fan or blower an

Page 20

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Start-Up Dust Control Systems (continued) Note: If the pressure drop continu

Page 21

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 4-6 Section 5 - Component Information The following pages show details of the

Page 22 - Section 4 - Operation

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 5-1 Explosion Vents (if applicable) - Confirm Vent(s) with Camcorp Camcorp P/N

Page 23 - Start-Up Checklist

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 6 - TROUBLESHOOTING Dust Collector...

Page 24

SPECIFICATIONSDimensions: 4-3/4" dia. X 2-3/16" deep.Weight: 1 lb. 2 oz.Finish: Baked dark gray enamel.Connections: 1/8 N.P.T high and low

Page 25

MAGNEHELIC®INSTALLATION1. Select a location free from excessive vibrationand where the ambient temperature will notexceed 140°F Also, avoid direct sun

Page 26

MAINTENANCEBULLETIN NO. A-27Page 3Maintenance: No lubrication or periodic servic-ing is required. Keep case exterior and coverclean. Occasionally disc

Page 27 - Shutdown Procedures

BULLETIN NO. A-27Page 4Magnehelic®GageEXPLODED VIEWSeries 2000Ordering Instructions:When corresponding with the factory regarding Magnehelic®gage prob

Page 28

Phone 800-323-2593630-231-5900Fax 630-231-1377National ControlsCorporation4ContentsPreviousNext4-8Features File #E65038 Digital Timing Circuitry:

Page 29

Phone 800-323-2593630-231-5900Fax 630-231-1377National ControlsCorporation4ContentsPreviousNext4-98”x 6”x 31/2”10” x 8” x 4”Accessories:CADB.25.31

Page 30 - Differential Pressure Gage

Phone 800-323-2593630-231-5900Fax 630-231-1377National ControlsCorporation4ContentsPreviousNext4-12Features Field Selectable from 2 to10 Outputs C

Page 31 - INSTALLATION

Phone 800-323-2593630-231-5900Fax 630-231-1377National ControlsCorporation4ContentsPreviousNext4-13National Controls Corporation offers NEMA 4 typ

Page 32 - MAINTENANCE

Specifications – Installation and Operating InstructionsBULLETIN E-97Series DCT1000 Dust Collector Timer ControllerThank you for purchasing the DCT100

Page 33 - Series 2000

Table of Contents . . . . . . . . . . . . . . . .Page No.1.0 Installing the DCT1000 . . . . . . . . . . . . . . .21.1 Power Requirements . . . . . .

Page 34 - Controls

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 1 – Safety Recommendations Because this unit may be under pressure or

Page 35 - Click for Where to Buy

4-20 mA ConnectionsReceiverUsing DCT100024V SupplyLowLimitHighLimitPressureLimitSwitches+-Receiver+-Optional ConnectionUsing ExternalPower Supply+Supp

Page 36

when routing the air hoses to ensure that any potential con-densation or moisture will not drain into the sensor. Whereheavy condensation is present,

Page 37 - 12-24VDC ONLY

available. You will note that both the master controllers andslave boards have a telephone style connector mounted onthe upper right hand side of the

Page 38 - BULLETIN E-97

63.6 High Alarm SetupThe operation of the High Alarm Setup is identical to the Highand Low Limit Setup and is only available when a pressuremodule is

Page 39 - 1.0 Installing the DCT1000

74.4 Error CodesError codes will be displayed on the three-digit display whencertain faults occur. Most of these indicators are associatedwith the d

Page 40 - Normally Open Contacts

Still need help? Please feel free to contact one of our customer service representatives at219-879-8000 or visit us on the web at www.dwyer-inst.com o

Page 44 - 5.0 Glossary of Terms

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 6- Troubleshooting Troubleshooting the Dust Collector Excessive Pres

Page 45 - Lit-by-Fax: 888/891-4963

Examples of Safety Stickers CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com ------DANGER------ The DANGER & CA

Page 46

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Troubleshooting the Dust Collector (continued) Filter Cartridges Loaded with D

Page 47

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Troubleshooting the Dust Collector (continued) Condensation If moisture has be

Page 48

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Troubleshooting the Dust Collector (continued) Continuous Flow of Dust in the

Page 49 - Section 6- Troubleshooting

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Troubleshooting the Dust Collector (continued) Chemical attack Filter material

Page 50

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Troubleshooting the Compressed Air System Pulsing failure of all valves or the

Page 51 - Extremely Low Pressure Drop

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 7 – Routine Maintenance Inspection Frequency will vary as widely as

Page 52

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 8 – Appendix Dust Collection Terms & Definitions Air-to-Cloth R

Page 53 - Troubleshooting the Timer

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Magnehelic Gauge – A standard devise used to measure differential pressure. Pr

Page 54

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 2 - Receiving Receiving the Equipment Prior to accepting the shipment

Page 55 - Repairs

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Storage Recommendations Baghouse, Bin Vent, Filter Receiver, Dirty Air Hopper

Page 56 - Section 8 – Appendix

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Storage Recommendations (continued) Accessory Parts • This includes all ga

Page 57

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Storage Recommendations (continued) Isolation Dampers • All limit switches,

Comments to this Manuals